The following steps are recommended for installation.
On structural subfloor (plywood, particleboard, concrete. tiles or existing timber floor) over joists.
1- All subfloor must be stable, firm, dry, clean and free from but not limited to dust, nails, Oil and sharp objects,
2- All subfloor must be level and variation must not exceed 3-4mm over 4m2.
3- A 10mm spaces around the parameter is required skirting or profiles no less than 15mm thickness must not be fixed to the flooring.
4- Moisture in Subfloor (Concrete, Timber, Tiles and / or but not limited) must not exceed more 6-8%. In case above 8% please seek professional advice from licenced floorer or builder.
5- Please make sure you use ONLY Euroak Flooring® recommended UNDERLAY and / or Eurobond Flooring Adhesive, otherwise please obtain a written approval from Euroak Flooring®.
6- PVA glue must be applied between Tongue and Groove, excessive glue should be cleaned off immediately. In case of using Eurobond Flooring Adhesive please refer to product (MSDS) material safety data sheet.
7- Delaminated, lifting and separation between boards can be the result but not limited of water damage, poor ventilation and high moisture in the installation areas. Please make sure to seek professional advise from licenced floorer or builder before installation.
8- Please keep thorough testing records including RH (Relative Humidity), PH level in subfloor, Moisture Content level. MC (Moisture level in concrete cannot exceed more 6-8% if it over please seek professional advice from a licenced floorer or builder.